Skip to main content

Functional Analogues

This reference maps Old XINA tools and features to New XINA workflows. For any given thing you might have done in an Old XINA tool, how can you do it now?

Old XINA Tools

Alerts

Implemented in the Events tool

HK

Primarily implemented in the Mnemonic Plot tool

The Mnemonic Plot tool functions very similarly to the HK tool, except:

  • Any time range can be selected
  • The zoom chart is not needed
Old XINA New XINA
Change the model Interface is unchanged.
Search and select a TID Use the "Select Time Range" card's TID Search tab.
Select comparison TIDs Use the Mnemonic Trending tool to select multiple disjoint time ranges.
Change housekeeping bin mode Change bin sizes or disable altogether in the "Binning" dropdown in the top left. For marker bins, use the Mnemonic Trending tool.
Quick-select an ESOH Use the Plot Configurations offcanvas in the top right. You can also "favorite" individual mnemonics by clicking their stars in the "Select Mnemonics" card.
Search and select housekeeping channels Use the "Select Mnemonics" card.
View and manage expected values Management is most easily done through the Nominal Range Export tool, but can be done in the Mnemonic Plot tool like so: If the Nominal Ranges table is not already visible, above the chart, click the gear to expand advanced settings, and then check "Show Nominal Ranges". To create a new Nominal Range, click the "+" button at the top right of the table. To edit an existing Nominal Range, click its "Edit" button.
Change a y axis's label Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change or disable the "Title Text" and "Apply".
Change a y axis's position, left vs right Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change the "Side" setting and "Apply".
Use a log scale for a y axis Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, check the "Log Axis" setting and "Apply".
Provide an explicit maximum or minimum to a y axis Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, you change the minimum and maximum and "Apply".
Change a mnemonic to show just the average, min, max, or range of each bin Open the mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change the "Sub-Channel" to the desired value.
Split a mnemonic to its own axis Interface is unchanged.
Combine two y axes Interface is unchanged.
Add markers and messages to the plot To search, use the "Select Events" card in the bottom left. Or, if "Show Nearest Event" is enabled in the chart's advanced settings, markers and messages will appear as you hover over the chart. If you click on one, a modal appears, and the top right has a button to pin or unpin it.
Stacked Chart Viewer Above the chart, click the gear to expand advanced settings, and then enable "Stack Y Axes". If desired, split each mnemonic to its own y axis through the Mnemonic Select card.
Edit or disable the chart's title Open the chart's settings modal, either through the chart button above the chart or by right-clicking the chart. There, change or disabled the title and "Apply".
Change the x axis mode Interface is unchanged, but there are new options.
Configure an offset for comparison TIDs No longer supported; please request if needed.
With comparison TIDs, use the "difference" reference mode No longer supported; please request if needed. Some related functionality can be achieved through Mnemonic Reference Values.
Display limits for a mnemonic If the Nominal Ranges table is not already visible, above the chart, click the gear to expand advanced settings, and then check "Show Nominal Ranges". In that table, toggle the "Plot" button for any ranges to the desired display mode.
Change the zoom mode Above the chart, click the gear to expand advanced settings, and then use the "Zoom" dropdown.
Show expected values If the Nominal Ranges table is not already visible, above the chart, click the gear to expand advanced settings, and then check "Show Nominal Ranges". In that table, toggle the "Plot" button for any ranges to the desired display mode.
Show points Above the chart, click the gear to expand advanced settings, and then check "Show Points".
Everything to do with the zoom chart The zoom chart is no longer used. Instead, the entire plot can be binned or unbinned as desired. If you want to minimize data loading, you can use "Automatic"-sized bins, manually zoom in on the chart, and then click "Load Time from View" above the chart.
Step the time window forwards, backwards, or out from the chart Use the "Expand Time Window" button above the chart to expand the view by 25% in each direction.
View statistics for selected mnemonics Above the chart, click the gear to expand advanced settings, and then check "Show Statistics".

HK MK Comparison Trending

Deprecated, but largely implemented in the Mnemonic Trending tool

Implemented in the Mnemonic Trending tool

The Mnemonic Trending tool functions very similarly to the various HK Trending tools, in a more generic form. The biggest differences from the HK MK Delta Trending tool are:

  • The "end markers" are just the selected markers, like the HK Marker Trending tool.
  • The "delta" functionality is now configured per mnemonic, through the mnemonic settings modal.
Old XINA New XINA
Change the model Interface is unchanged.
Search and select TIDs Not yet supported. Markers can be searched directly, without limiting to particular TIDs.
Search and select the start markers This is very different. For each mnemonic, open its mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change the "Reference Value Mode" to either select "By Event Definition" to select by Marker ID or "By Event" to select markers individually. Use the appropriate interface to search and select events, and then "Apply".
Search and select the end markers Use the "Select Intervals" card.
Search and select a TID Use the "Select Time Range" card's TID Search tab.
Select comparison TIDs Use the Mnemonic Trending tool to select multiple disjoint time ranges.
Quick-select an ESOH Use the Plot Configurations offcanvas in the top right. You can also "favorite" individual mnemonics by clicking their stars in the "Select Mnemonics" card.
Search and select housekeeping channels Use the "Select Mnemonics" card.
View and manage expected values Management is most easily done through the Nominal Range Export tool, but can be done in the Mnemonic Plot tool like so: If the Nominal Ranges table is not already visible, above the chart, click the gear to expand advanced settings, and then check "Show Nominal Ranges". To create a new Nominal Range, click the "+" button at the top right of the table. To edit an existing Nominal Range, click its "Edit" button.
Change a y axis's label Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change or disable the "Title Text" and "Apply".
Change a y axis's position, left vs right Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change the "Side" setting and "Apply".
Use a log scale for a y axis Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, check the "Log Axis" setting and "Apply".
Provide an explicit maximum or minimum to a y axis Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, you change the minimum and maximum and "Apply".
Change a mnemonic to show just the average, min, max, or range of each bin Open the mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change the "Sub-Channel" to the desired value.
Split a mnemonic to its own axis Interface is unchanged.
Combine two y axes Interface is unchanged.
Edit or disable the chart's title Open the chart's settings modal, either through the chart button above the chart or by right-clicking the chart. There, change or disabled the title and "Apply".
Use the Avg-Range delta mode For each mnemonic, set up a "Reference Value" with a "Reference Value Channel" of "Avg", and set "Sub-Channels" to "All". To do this, open each mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, make the appropriate changes and "Apply".
Use the Min-Max delta mode For each mnemonic, set up a "Reference Value" with a "Reference Value Channel" of "Min", and set "Sub-Channels" to "Max". To do this, open each mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, make the appropriate changes and "Apply".
Change the x axis mode Interface is unchanged, but there are new options.
Show expected values If the Nominal Ranges table is not already visible, above the chart, click the gear to expand advanced settings, and then check "Show Nominal Ranges". In that table, toggle the "Plot" button for any ranges to the desired display mode.
Show points Above the chart, click the gear to expand advanced settings, and then check "Show Points".
Click a chart point to view its full data in the HK tool Interface is unchanged.

Implemented in the Mnemonic Trending tool

The Mnemonic Trending tool functions very similarly to the various HK Trending tools, in a more generic form. The biggest difference from the HK MK Trending tool is that the "reference marker" and reference mode is now configured per mnemonic, through the mnemonic settings modal.

Old XINA New XINA
Change the model Interface is unchanged.
Search and select TIDs Not yet supported. Markers can be searched directly, without limiting to particular TIDs.
Search and select markers Use the "Select Intervals" card.
Search and select a reference marker This is very different, depending on desired effect. If the "Overlay" ref mode is desired, simply select the marker using the "Select Intervals" card. If the "Diff" ref mode is desired, you must configure a Reference Value: For each mnemonic, open its mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change the "Reference Value Mode" to "By Event". Use the interface to search and select the desired marker, and then "Apply".
Quick-select an ESOH Use the Plot Configurations offcanvas in the top right. You can also "favorite" individual mnemonics by clicking their stars in the "Select Mnemonics" card.
Search and select housekeeping channels Use the "Select Mnemonics" card.
View and manage expected values Management is most easily done through the Nominal Range Export tool, but can be done in the Mnemonic Plot tool like so: If the Nominal Ranges table is not already visible, above the chart, click the gear to expand advanced settings, and then check "Show Nominal Ranges". To create a new Nominal Range, click the "+" button at the top right of the table. To edit an existing Nominal Range, click its "Edit" button.
Change a y axis's label Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change or disable the "Title Text" and "Apply".
Change a y axis's position, left vs right Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change the "Side" setting and "Apply".
Use a log scale for a y axis Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, check the "Log Axis" setting and "Apply".
Provide an explicit maximum or minimum to a y axis Open the axis's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, you change the minimum and maximum and "Apply".
Change a mnemonic to show just the average, min, max, or range of each bin Open the mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, change the "Sub-Channel" to the desired value.
Split a mnemonic to its own axis Interface is unchanged.
Combine two y axes Interface is unchanged.
Edit or disable the chart's title Open the chart's settings modal, either through the chart button above the chart or by right-clicking the chart. There, change or disabled the title and "Apply".
Change the x axis mode Interface is unchanged, but there are new options.
Change the x axis labels Not yet supported. Coming soon.
Use the "Diff" ref mode For each mnemonic, set up a "Reference Value", with "Reference Value Mode" set to "By Event" and the desired reference event selected, and whatever desired "Reference Value Channel". To do this, open each mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, make the appropriate changes and "Apply".
Change the reference "Diff" type between Avg, Min, and Max For each mnemonic, set up a "Reference Value", with "Reference Value Mode" set to "By Event" and the desired reference event selected, and with "Reference Value Channel" set to "Avg", "Min", or "Max" as desired. To do this, open each mnemonic's settings modal, either through the gear button next to it in the mnemonic selection or by right-clicking the chart. There, make the appropriate changes and "Apply".
Display limits for a mnemonic If the Nominal Ranges table is not already visible, above the chart, click the gear to expand advanced settings, and then check "Show Nominal Ranges". In that table, toggle the "Plot" button for any ranges to the desired display mode.
Show expected values If the Nominal Ranges table is not already visible, above the chart, click the gear to expand advanced settings, and then check "Show Nominal Ranges". In that table, toggle the "Plot" button for any ranges to the desired display mode.
Show points Above the chart, click the gear to expand advanced settings, and then check "Show Points".
Click a chart point to view its full data in the HK tool Interface is unchanged.

Deprecated, but largely implemented in the Mnemonic Trending tool

LTQ

Implemented in the Spectra Viewer tool

Marker Log

Implemented in the Events tool

Implemented in the Events tool

Message Log

Implemented in the Events tool

Implemented in the Events tool

Implemented in the Carousel tool

MOMA Chromatogram

Deprecated, but largely implemented in the Spectra Viewer tool

MOMA Contamination Trending

Deprecated, but largely implemented in the Spectra Viewer tool

MOMA DAC Scan Viewer

Implemented in the Spectra Viewer tool

MOMA Diagram

Implemented in the Diagram tool

MOMA GCMS Chart

Deprecated, but largely implemented in the Mnemonic Plot tool

MOMA Laser Tool

Implemented in the Mnemonic Plot tool

MOMA ML Dimensionality Reduction

Implemented in the MOMA Machine Learning tool

MOMA ML Export

Implemented in the MOMA Machine Learning tool

MOMA Ops

Implemented in the Operations tool

MOMA Ops Training

Implemented in the Operations Training tool

Deprecated

MOMA Sample Info

Implemented in the Carousel tool

MOMA Sample Science Trending

Deprecated, but largely implemented in the Spectra Viewer tool

MOMA Sample Viewer

Implemented in the Carousel tool

MOMA Science Trending

Implemented in the Spectra Viewer tool

MOMA Spectra Tool

Deprecated, but largely implemented in the Spectra Viewer tool

MOMA Timeline

Implemented in the Mnemonic Plot tool and Model Info interface