Alerts Alerts are messages generated during mining that often serve as a notice or warning that a certain threshold or event occurred. Each alert contains a severity, a time, and a specific message. MOMA Alerts General Error Check Alert ID: 1 Severity: Notice Description: Grep message log for "Error" MAIF APV Comm Alert ID: 2 Severity: Warning Description: Grep message log for "ldi: error" Spacewire Comm Error Alert ID: 3 Severity: Warning/Notice Description: Spacewire Parity (HK 522) > 0 or Spacewire Disconnect (HK 523) > 0 after 30sec MOMA Safe Event Alert ID: 4 Severity: Notice Description: HK 507 MAX, MOMA_STATUS_SAFE > 0 at any time during a TID WRP Too Fast Alert ID: 5 Severity: Notice Description: PWM Speed - HK 832 MAX > 103000 WRP Failed To Start Alert ID: 6 Severity: Warning Description: PWM Speed - HK 832, MAX > 1000 and < 99000 RPM WRP Pressure Spike Alert ID: 7 Severity: Warning Description: HK 830, MOT_SUP_IMON, MAX > 1.1A Dark Counts Alert ID: 8 Severity: Warning Description: HK 252 SCAN_TELEM_DAC_ID = 20000 AND HK 253 SCAN_TELEM_DAC_VAL > 5 Laser Burst Energy Variation Alert ID: 9 Severity: Info Description: Std. Dev. of burst pulse energy is > 5.0 Laser Pulses Mismatch Alert ID: 10 Severity: Notice Description: Main Pulses != # of Pulses in Burst Unknown SEB sequences Alert ID: 11 Severity: Notice Description: Scan type is LDI or EI, and SEB packet sequence count == 0 Filament VMON Pegged Alert ID: 12 Severity: Warning Description: Anytime Filament VMON HK is > 4.9 Expected Pulse Count Mismatch Alert ID: 13 Severity: Warning Description: HKID 1050 (PLS_SUBPKT_CNT) != (pkt.length() - 4 / 16) Gap in Scans Alert ID: 14 Severity: Warning Description: Bin Delta between Science packets is > 100 Old Packet Format Alert ID: 15 Severity: Info Description: Scan Packet Version Number != 2 (c_scan.science_data_pkt_version()) Missing Scan Status Packets Alert ID: 16 Severity: Warning Description: Number of Scan Status Packets != Number of Scans in Summed Packet | Disable for Dark Counts Dropped Packets Alert ID: 17 Severity: Warning Description: Dropped packets are detected by gaps in the packets' sequence numbers. Both EMs On Alert ID: 18 Severity: Warning Description: Both Electron Multipliers are on at the same time Sub-system Communication Errors Alert ID: 19 Severity: Warning Description: Communication errors between any of the sub-systems (MAIF, SEB, GC, LASER) as reported by the CDH/FSW. WRP Instantaneous High Current Alert ID: 20 Severity: Warning Description: The instantaneous WRP Current exceeded a threshold. A Problem Report should be opened if it happened on the Flight Model. Mass Flow WRP Back Pressure Instant WRP Current MP_PRESS < 0.5 4 Torr 0.55 A MP_PRESS < 0.5 6 Torr 0.65 A MP_PRESS < 0.5 8 Torr 0.75 A MP_PRESS > 0.5 4 Torr 0.70 A MP_PRESS > 0.5 6 Torr 0.80 A MP_PRESS > 0.5 8 Torr 0.90 A WRP 1-Min Average High Current Alert ID: 21 Severity: Warning Description: The 1-Min Avg WRP Current exceeded a threshold. A Problem Report should be submitted if it happened on the Flight Model. Mass Flow WRP Back Pressure 1-Min Avg WRP Current MP_PRESS < 0.5 4 Torr 0.45 A MP_PRESS < 0.5 6 Torr 0.55 A MP_PRESS < 0.5 8 Torr 0.65 A MP_PRESS > 0.5 4 Torr 0.60 A MP_PRESS > 0.5 6 Torr 0.70 A MP_PRESS > 0.5 8 Torr 0.80 A